- Safety switch with integrated evaluation electronics
- Pulsed signals can be switched
- 2 safety outputs (semiconductor outputs)
- Category 3 / PL e according to EN ISO 13849-1
Approach direction: Can be adjusted in 90° steps
Unicode evaluation: Each actuator is highly coded (unicode). The switch detects only taught-in actuators. Additional actuators can be taught-in.
Category according to EN ISO 13849-1: Due to two redundantly designed semiconductor outputs (safety outputs) with internal monitoring suitable for: Category 3 / PL e according to EN ISO 13849-1
The actuating range may vary depending on the substrate material and installation situation.
Workspace:
Repeat accuracy R: according to EN 60947-5-2 10 %
Operating and display elements:
LED display: Safety outputs status / diagnostics LED (combined)
Status LED
Electrical connection values:
Fuse (external) operating voltage: 0.25 ... 8 A
Rated insulation voltage Ui: 75 V
Rated impulse voltage Uimp: 1.5 kV
Operating voltage DC: 18 ... 24 ... 27 V DC regulated, residual ripple<5%
EMC protection requirements: Acc. to EN IEC 60947-5-3
Current consumption: 80 mA
Degree of contamination (external, according to EN 60947-1): 3
Monitoring output OUT:
Output type: Semiconductor output, p-switching, short circuit-proof
Output voltage: 0.8 x UB ... UB V DC
Switching current: max. 20 mA
Safety outputs LA / LB
Fuse: external, safety circuit U(+LA) / U(+LB) 0.4 A medium slow-blow
Output type: Semiconductor outputs, p-switching, short circuit-proof, electrically decoupled
Output voltage:
LOW U(LA) / U(LB) 0 ... 1 V DC
HIGH U(LA) U(+LA) - 1.5 ... U(+LA) V DC
HIGH U(LB) U(+LB) - 1.5 ... U(+LB) V DC
rated conditional short-circuit current: 100 A
Discrepancy time: (between the operating points of both safety outputs) max. 120 ms
Utilization category: DC-13 Safety outputs LA / LB 24 V 400 mA
Switching load: according to UL max. DC 24 V, Class 2
Switching current : per safety output 1 ... 400 mA
Power supply output load: U(+LA) / U(+LB) 18 ... 24 ... 27 V DC
Mechanical values and environment:
Dimensions: according to EN 60947-5-2: (LxWxH) 131x40x40
Connection type: M12 plug connector, 8-pin; shield can be connected
Tightening torque: Screws, read head mounting bracket max. 0.6 Nm
Fixing screws, housing max. 1 Nm
Ready delay: max. 3 s
Installation orientation: any
Switching frequency: max. 1 Hz
Mounting distance: between switches min. 80 mm
Response time: after change in the actuation status max. 180 ms
Degree of protection IP65/IP67
Ambient temperature: with UB = 24 V DC -20 ... +55 °C
Dwell time: min. 0.5 s
Material: Housing Plastic, PBT
Ordernumber: 077750
Item designation: CES-A-C5E-01
Customs tariff number: 85365019000
ECLASS: 27-27-24-03 Safety-related transponder switch
Weight: 0,350 kg
Price 1.01 = negotiated price
Made in Germany.